Disposable Pressure Transducer
Category:
- Features
- Details
-
- Commodity name: Disposable Pressure Transducer
Can montor patients'venous pressure and arterial pressure,can continuously and real-time monitor systolic,diastolic and average pressure and rellect the patient provide relliable data in a timely manner for blood circulation,let clinicians understand cardiovascular function, and grasp the vital signs of patients
There are 9 different connectors: Abbott, Uber, BD,Edward, Argon,Bellon. PVB, USB, Mindray. Compatible with allcommon models on the market. There are blister boxes and simple bags
-
Main technical parameters and working environment requirements Baromelric pressure 70-106kpa Relative humidity 10-90% (non-candensing) Operating temperature range 15℃~40℃ Operating pressure range -50-+ 300mmHg Sansitivity 5.0μV/V/mmHg ±3% Nonlinearity and hysteresis full-scale readingt ±1.5% Input impedance 1200Ω-3200Ω Output impedance 300±5% Zero pressure oftset -20mmHg~+20mmHg Thermal offset shift ≤+0.3mmHg/℃ Offset drift Afler warm-up for 20 seconds, drift within 2 mmHg within 8 hours Thermal span shift ≤01%/℃ Frequency response Standard pressure set (48'/12") is 40 Hz; Separate senso r>200Hz Defibrillator withstand Defbrillation depends on the fnal connection of the equipment Risk Current (@120UAC rms, 60Hz) 2μA Overpressure load -400-+4000mmHg Shock resistance Withstand falling from one meter for three times Light sensitivity When exposed to a 3400K tungsten light, candle light at 3000 feet it's less Contact with the human body than 1 mmHg under rated woltage
≤168hStorage and transport environment requirements -20℃~+60℃, <90% (non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold Intra-system velocity 2-5mL/h (Intra-system velocity refers to the velocity under 6.00 VDC and 25℃, unless there are additional instructions.) Product shelf-life 3 years
- Features
- Details
-
- Commodity name: Disposable Pressure Transducer
Can montor patients'venous pressure and arterial pressure,can continuously and real-time monitor systolic,diastolic and average pressure and rellect the patient provide relliable data in a timely manner for blood circulation,let clinicians understand cardiovascular function, and grasp the vital signs of patients
There are 9 different connectors: Abbott, Uber, BD,Edward, Argon,Bellon. PVB, USB, Mindray. Compatible with allcommon models on the market. There are blister boxes and simple bags
-
Main technical parameters and working environment requirements Baromelric pressure 70-106kpa Relative humidity 10-90% (non-candensing) Operating temperature range 15℃~40℃ Operating pressure range -50-+ 300mmHg Sansitivity 5.0μV/V/mmHg ±3% Nonlinearity and hysteresis full-scale readingt ±1.5% Input impedance 1200Ω-3200Ω Output impedance 300±5% Zero pressure oftset -20mmHg~+20mmHg Thermal offset shift ≤+0.3mmHg/℃ Offset drift Afler warm-up for 20 seconds, drift within 2 mmHg within 8 hours Thermal span shift ≤01%/℃ Frequency response Standard pressure set (48'/12") is 40 Hz; Separate senso r>200Hz Defibrillator withstand Defbrillation depends on the fnal connection of the equipment Risk Current (@120UAC rms, 60Hz) 2μA Overpressure load -400-+4000mmHg Shock resistance Withstand falling from one meter for three times Light sensitivity When exposed to a 3400K tungsten light, candle light at 3000 feet it's less Contact with the human body than 1 mmHg under rated woltage
≤168hStorage and transport environment requirements -20℃~+60℃, <90% (non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold Intra-system velocity 2-5mL/h (Intra-system velocity refers to the velocity under 6.00 VDC and 25℃, unless there are additional instructions.) Product shelf-life 3 years